當前位置:首頁產品中心離心機臺式大容量離心機SG-852-type large-capacity centrifuge
large-capacity centrifuge

產品簡介

SG-852-type large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產品型號:SG-852-type
更新時間:2019-05-05
廠商性質:生產廠家
訪問量:3354
詳細介紹在線留言

Product Introduction:
SG-852-type large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select
Technical data:
Maximum speed: 5000r/min
1 rotor: 4 * 100ml
No. 2 rotor: 8 * 50ml
No. 3 rotor: 28 * 10ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees - 60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

在線留言

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

掃碼加微信,了解最新動態(tài)

掃碼加微信
021-65682142

Copyright © 2025 上海碩光電子科技有限公司版權所有

技術支持:化工儀器網    sitemap.xml

滬公網安備 31011002005640號

欧美一区二区三区| 中文字幕人妻丝袜二区| 国产卡一卡二卡三乱码手机| 肉干欢乐颂五美| gogogo免费观看日本| 凹凸在线无码免费视频| 精品国产_亚洲人成在线观看| 高傲人妻女教师的沉沦长篇| 国内露脸少妇精品视频| 欧美一区二区三区| 久久久人人人婷婷色东京热| 1区2区3区产品乱码免费| 国产自啪免费精品视频浪潮AV| 亚洲av成人片色在线观看高潮| 亚洲 国产 日韩 在线 一区| 人妻丰满熟妇aⅴ无码| 我控制不住我想要你| 色老太BBWBBWBBW高潮| 秘书在办公室被躁bd在线观看| 国产丰满老熟女重口对白| 免费看无码自慰一区二区| A片扒开双腿进入做爽爽| 老师含着我的奶边摸边做| 亚洲精品又粗又大又爽a片| GOGO国模私拍大尺度| 高潮久久久久久久久不卡| 亚洲色欲色欲www在线丝| 最近免费中文字幕中文高清6| 日本三级吃奶头添泬| 无码少妇一区二区三区芒果| 亚洲AV永久无码国产精品久久 | 肉浦团在线观看| 第一次交换完美邻居| 国产丝袜美女一区二区三区| 外国四个黑人RAPPER组合| 国产精品人人做人人爽| 日本熟妇毛茸茸| 久久久亚洲AV成人网站| 乖让我尿到里面H| 无人在线观看完整免费版视频| 久视频精品免费观看99|